Error Code explanation

Error Code explanation

  • Look for the LED indicator if you have a charger without screen

Error CodeErrorDescriptionLED ColourResolutionNotes
0Contactor WeldedContactor issueREDDisconnect car, power cycle chargerConstant fault requires on site visit
1Contactor does not respondContactor issueREDDisconnect car, power cycle chargerConstant fault requires on site visit
2Interlock ErrorInterlock issueREDCheck Charging cable is fully inserted, remove and reinsert cableConstant fault requires on site visit
3Interlock unlock errorInterlock issueREDCheck Charging cable is fully inserted, remove and reinsert cableConstant fault requires on site visit
4Proximity Pilot ErrorCommunication errorREDRemove and reinsert charging cableConstant fault requires on site visit
5CP DiodeCommunication errorREDRemove and reinsert charging cable
6CP ShortCommunication errorREDRemove and reinsert charging cable, Try an alternative cable Constant fault requires on site visit
7Over Voltage phase 1Voltage above 270VREDPower cycle deviceSupply voltage and cable terminations should be checked, Constant fault requires on site visit
8Over Voltage phase 2Voltage above 270VREDPower cycle deviceSupply voltage and cable terminations should be checked, Constant fault requires on site visit
9Over Voltage phase 3Voltage above 270VREDPower cycle deviceSupply voltage and cable terminations should be checked, Constant fault requires on site visit
10Under Voltage phase 1Voltage under 190VREDPower cycle deviceSupply voltage and cable terminations should be checked, Constant fault requires on site visit
11Under Voltage phase 2Voltage under 190VREDPower cycle deviceSupply voltage and cable terminations should be checked, Constant fault requires on site visit
12Under Voltage phase 3Voltage under 190VREDPower cycle deviceSupply voltage and cable terminations should be checked, Constant fault requires on site visit
13Over Current Phase 1Current above set valuePURPLECheck Property usage, if low then the charging session will resume. Setting should be checked and confirmed correctError can be related to vehicle, disconnect and reconnect vehicle
14Over Current Phase 2Current above set valuePURPLECheck Property usage, if low then the charging session will resume. Setting should be checked and confirmed correctError can be related to vehicle, disconnect and reconnect vehicle
15Over Current Phase 3Current above set valuePURPLECheck Property usage, if low then the charging session will resume. Setting should be checked and confirmed correctError can be related to vehicle, disconnect and reconnect vehicle
16Residual Current ErrorDC leakage is above 6mAREDRemove charging cable and re connect. Power cycle.Constant fault requires on site visit
17Protective Earth or Phase Reversal faultEarth fault or incorrect phase connectionREDPower Cycle deviceSupply cable connection to be checked, if ok then a earth reading should be measured.
18RFID Reader ErrorRFID ErrorREDCheck correct (authorised) RFID cards are used. Power cycle deviceConstant fault requires on site visit
19Connector lock failureInterlock issueREDRemove charging cable and reconnect. Try alternative car or cableConstant fault requires on site visit
20Over Current FailurePermanent error cause by overcurrent during 3 attempts to chargePURPLEAvailable power is too low due to usage. Reduce consumption by other appliances. Power cycle deviceConstant fault requires on site visit
22Power optimiser communication errorIssue with Power optimiser set upREDSettings should be checked. CT Clamp or external meter checked. Reset power optimiser settings and power cycle deviceConstant fault requires on site visit
24External RFID ErrorRFID Reader errorREDRFID Cable should be checkedOnsite Visit required
25Power Meter FailureMID Communication errorREDSettings should  be checked, Power cycle deviceConstant fault requires on site visit
26RCD Device ErrorInternal RCD error (DC leakage)REDPower cycle deviceConstant fault requires on site visit
27Installation ErrorSupply cable connection error or Incorrect rotary switch positionREDCheck L and N connections are correct. Check Rotary switch is in correct positionConstant fault requires on site visit
28PEN errorSupply Voltage is outside range of 207 to 253VREDPower cycle the device (Firmware update will incorporate a auto reset, available early 2025)Auto reset to be available 2025
29Emergency Switch ErrorDC Products OnlyN/A
30Board Communication ErrorInternal communication errorREDwill automatically reset when cleared, power cycle deviceConstant fault requires on site visit
31TIC Communication ErrorPower optimisation with external meter(Modbus)REDIncorrect settings selected on P/O

    • Related Articles

    • What should I do if the charger shows an error?

      The charger provides a detailed error list for issues like Contactor Welded or Over Voltage Phase. Refer to the error code and contact support if necessary.
    • How can I join a Zone?

      Joining a Charging Zone: Obtain the Joining Code: Ensure you have the correct joining code for the charging zone you wish to join. For New Users: If no charging zones are listed in your account, locate the "Join zone" button on the Zone screen. Tap ...
    • How to Commission a Vestel Charger with a SIM (4G Connection)?

      Follow the steps below to commission your Vestel charger using mobile data (4G) Step 1: Select the charger Open the Installer Miles app Choose Access as Installer Select the charger make Choose the charger model Step 2: Scan the charger Scan the QR ...
    • How do I commission an EVIQ charger using Bluetooth with the Installer Miles app?

      Here's a step-by-step guide: Open the Installer Miles App: Launch the Installer Miles application on your mobile device. Enable Bluetooth: Ensure that both Bluetooth and GPS are turned on in your mobile device's settings. Select Charger and ...
    • How do I start the commissioning process?

      Open the Installer Miles app, turn on Bluetooth on your mobile device, select your charger make and model, and scan the QR code or enter it manually.